![]() It frequently interferes with accurate detection of abundant proteins, including HKP loading controls. Membrane saturation is the result of sample overloading.Error introduced by saturation may alter data analysis and interpretation. Intensity of strong bands is underestimated, interfering with comparison of relative protein levels across the blot. Saturated bands yield similar intensity values, regardless of the actual amount of target present, and cannot be accurately quantified. Saturation occurs when increasing amounts of target fail to produce the expected increase in band intensity. Dotted lines indicate loss of proportionality on the upper and lower ends of the linear range. Combine these ranges to identify a level of sample loading that will produce a linear response for both. Determine the linear range separately for the target and internal loading control. In the linear range of detection, the target and internal loading control both display a linear relationship between sample loading and band intensity. Band intensity no longer reflects the abundance of target, and quantification is not possible. At the upper and lower ends of the linear range, this proportional relationship is lost. For example, a two-fold increase in sample loading is expected to produce a two-fold increase in band intensity. A change in target abundance should produce an equivalent change in signal response. Within the linear range of detection, band intensity should be proportional to the amount of target. Outside this range, signal intensity is not dependent on sample loading and does not accurately reflect the amount of target. In QWB analysis, the linear range of detection is the range of sample loading that produces a linear relationship between the amount of target on the membrane and the band intensity recorded by the detector ( Figure 45). Linear Range, Saturation, and Proportional Signals The combined linear range is then used to determine how much sample should be loaded to produce a linear signal response for both the target protein and the internal loading control ( Figure 45).Įmpiria Studio® Software provides a dedicated workflow for this process. QWB analysis is accurate only if the target protein and internal loading control can both be detected within the same linear range – a range that must be determined experimentally for each target and loading control. The internal loading control is used as an indicator of sample protein loading, to correct for loading variation and confirm that changes observed in target protein bands represent actual differences between samples. In quantitative Western blotting (QWB), normalization mathematically corrects for unavoidable sample-to-sample and lane-to-lane variation by comparing the target protein to an internal loading control. Determining the Linear Range for Quantitative Western Blot Detection Introduction
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |